dc.contributor.author | Κάβουρας, Διονύσης Α. | el |
dc.contributor.author | Norton Wayne, L. | en |
dc.date.accessioned | 2015-04-29T07:23:54Z | |
dc.date.available | 2015-04-29T07:23:54Z | |
dc.date.issued | 2015-04-29 | |
dc.identifier.uri | http://hdl.handle.net/11400/9226 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://www.sciencedirect.com/science/article/pii/003132038190042X | en |
dc.subject | Tomographic reconstruction | |
dc.subject | Heart--Imaging | |
dc.subject | Τομογραφική ανασυγκρότηση | |
dc.subject | Καρδιακή απεικόνιση | |
dc.title | Tomographic mapping of the activity of the heart wall | en |
heal.type | journalArticle | |
heal.generalDescription | 1980 Conference on Pattern Recognition | en |
heal.classification | Medicine | |
heal.classification | Biomedical engineering | |
heal.classification | Ιατρική | |
heal.classification | Βιοϊατρική τεχνολογία | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh85014237 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Βιοϊατρική τεχνολογία | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh87005052 | |
heal.identifier.secondary | doi:10.1016/0031-3203(81)90042-X | |
heal.language | en | |
heal.access | campus | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 1981 | |
heal.bibliographicCitation | Cavouras, D. and Norton Wayne, L. (1981). Tomographic mapping of the activity of the heart wall. Pattern Recognition. 14(1-6). pp. 17-32, 1981. Elsevier B.V.: 1981. Available from: http://www.sciencedirect.com/science/article/pii/003132038190042X [Accessed 19/5/2003] | en |
heal.abstract | The paper describes a rapid and computationally efficient algorithm for producing a three-dimensional map of the distribution of radioisotope within the living human heart, from three two-dimensional Anger camera images. Two alternative versions of the algorithm are explained and compared. Degradations arising from photon attenuation, scattering and Poisson noise are ameliorated. | en |
heal.publisher | Elsevier B.V. | en |
heal.journalName | Pattern Recognition | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: