Εμφάνιση απλής εγγραφής

dc.contributor.author Μαυρίδου, Αθηνά el
dc.contributor.author Λαμπίρη, Μαρία el
dc.contributor.author Παπαδάκης, Ιωάννης Α. el
dc.date.accessioned 2015-04-30T21:48:49Z
dc.date.available 2015-04-30T21:48:49Z
dc.date.issued 2015-05-01
dc.identifier.uri http://hdl.handle.net/11400/9347
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.sciencedirect.com/science/article/pii/0043135494900590 en
dc.subject νόσος των Λεγεωνάριων
dc.subject θάνατος
dc.subject σύστημα νερού ξενοδοχείου
dc.subject Ελλάδα
dc.subject Legionnaires' disease
dc.subject fatality
dc.subject hotel water system
dc.subject Greece
dc.title A fatality resulting from a case of legionnaires' disease on hotel premises el
heal.type journalArticle
heal.classification Public health
heal.classification Chemistry
heal.classification Δημόσια υγεία
heal.classification Χημεία
heal.classificationURI http://lod.nal.usda.gov/28292
heal.classificationURI http://skos.um.es/unescothes/C00568
heal.classificationURI **N/A**-Δημόσια υγεία
heal.classificationURI **N/A**-Χημεία
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85075800
heal.keywordURI http://zbw.eu/stw/descriptor/17184-0
heal.identifier.secondary DOI: 10.1016/0043-1354(94)90059-0
heal.language en
heal.access campus
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας. Σχολή Επαγγελμάτων Υγείας και Πρόνοιας. Τμήμα Ιατρικών Εργαστηρίων el
heal.publicationDate 1994-11
heal.bibliographicCitation Mavridou, A., Lambiri, M. and Papadakis, J.A. (1994) A fatality resulting from a case of legionnaires' disease on hotel premises. Water Research. [Online] 28 (11), pp.2421-2423. Available from: http://www.sciencedirect.com [Accessed 30/04/2015] en
heal.abstract A fatal case of legionnaires' disease in a British tourist was contracted in a hotel on a Greek island. The air-conditioning system and the hot water system were checked for Legionella pneumophila. L.pneumophila ser 1 was investigated at two points, from a mixing valve and from a hot water tap at concentrations of 2000 and 3000 cfu/L respectively. Water temperature and abscence of free residual chlorine in the water are thought to be the factors that promoted the L.pneumophila proliferation in the water piping. Age and bad physical condition of the victim were probably of significance. en
heal.publisher Elsevier en
heal.journalName Water Research en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: 1-s2.0-0043135494900590-main.pdf
    Μέγεθος: 183.1Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες