Εμφάνιση απλής εγγραφής

dc.contributor.author Μαυρίδου, Αθηνά el
dc.contributor.author Καμμά, Ιωάννα el
dc.contributor.author Μανδηλαρά, Γεωργία el
dc.contributor.author Δελαπόρτας, Π. el
dc.contributor.author Κομιώτη, Φ. el
dc.date.accessioned 2015-05-01T21:11:16Z
dc.date.issued 2015-05-02
dc.identifier.uri http://hdl.handle.net/11400/9440
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.iwaponline.com/wst/05403/wst054030269.htm en
dc.subject Σύστημα νερού oδοντιατρικής μονάδας
dc.subject απολυμαντικά
dc.subject παθογόνα
dc.subject εκτίμηση κινδύνου
dc.subject Ελλάδα
dc.subject Dental unit water system
dc.subject disinfectants
dc.subject Pathogens
dc.subject risk assessment
dc.subject Greece
dc.title Microbial risk assessment of dental unit water systems in general dental practice in Greece en
heal.type journalArticle
heal.classification Environmental technology
heal.classification Microbiology
heal.classification Περιβαλλοντική τεχνολογία
heal.classification Μικροβιολογία
heal.classificationURI http://zbw.eu/stw/descriptor/15774-3
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00005932
heal.classificationURI **N/A**-Περιβαλλοντική τεχνολογία
heal.classificationURI **N/A**-Μικροβιολογία
heal.keywordURI http://lod.nal.usda.gov/221
heal.keywordURI http://id.loc.gov/authorities/subjects/sh00006928
heal.keywordURI http://zbw.eu/stw/descriptor/17184-0
heal.identifier.secondary DOI: 10.2166/wst.2006.479
heal.dateAvailable 10000-01-01
heal.language en
heal.access forever
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας. Σχολή Επαγγελμάτων Υγείας και Πρόνοιας. Τμήμα Ιατρικών Εργαστηρίων el
heal.publicationDate 2006
heal.bibliographicCitation Mavridou, A., Kamma, J., Mandilara, G., Delaportas, P. and Komioti, F. (2006) Microbial risk assessment of dental unit water systems in general dental practice in Greece. Water Science and Technology. [Online] 54 (3). p.269-273. Available from: http://www.iwaponline.com [Accessed 01/05/2015] en
heal.abstract Water was sampled from source water, the 3-in-1 syringe and the air rotor water line of dental unit water systems (DUWS) in general dental practice in Attica, Greece. A section of the water line supplying the 3-in-1 syringe was cut for biofilm analysis. High total viable counts, Mycobacterium spp. and Pseudomonas aeruginosa were detected in the samples. Back siphonage was evidenced by the presence of blood and the recovery of oral anaerobes from the samples. Legionella pneumophila was recovered from 16.1% of biofilm samples. All tested disinfectants reduced the total viable counts of the DUWS to <100 CFU/mL. en
heal.publisher IWA Publishing en
heal.journalName Water Science and Technology en
heal.journalType peer-reviewed
heal.fullTextAvailability false


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες