Εμφάνιση απλής εγγραφής

dc.contributor.author Ευαγγελόπουλος, Άγγελος el
dc.contributor.author Κολλημένου, Π. el
dc.contributor.author Βαλλιανού, Ν. el
dc.contributor.author Καρκαλούσος, Πέτρος el
dc.date.accessioned 2015-05-03T10:38:28Z
dc.date.issued 2015-05-03
dc.identifier.uri http://hdl.handle.net/11400/9538
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.bclf.info/ en
dc.source http://users.teiath.gr/petef/Web_CV/Presentations/Pre_Matrix_Attalya_2007.htm el
dc.subject Medical laboratory technology
dc.subject Quality control
dc.subject Quality Control Service
dc.subject Τεχνολογία ιατρικών εργαστηρίων
dc.subject Έλεγχος ποιότητας
dc.subject Υπηρεσία ελέγχου ποιότητας
dc.title Difference in control recovery in interlaboratory quality control schemes for immunoassays en
heal.type conferenceItem
heal.classification Medicine
heal.classification Technology
heal.classification Ιατρική
heal.classification Τεχνολογία
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://zbw.eu/stw/descriptor/10470-6
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Τεχνολογία
heal.keywordURI http://id.loc.gov/authorities/subjects/sh86002225
heal.keywordURI http://id.loc.gov/authorities/subjects/sh00005852
heal.dateAvailable 10000-01-01
heal.language en
heal.access forever
heal.recordProvider Σχολή Επαγγελμάτων Υγείας και Πρόνοιας. Τμήμα Ιατρικών Εργαστηρίων el
heal.publicationDate 2007
heal.bibliographicCitation Evaggelopoulos, A., Kollimenou, P., Vallianou, N. and Karkalousos, P. (2007) Difference in control recovery in interlaboratory quality control schemes for immunoassays. In "15th Balkan Conference of Clinical Chemistry". Attalya: Balkan Clinical Laboratory Federation. en
heal.abstract Introduction: Roche Diagnostics runs a quality control scheme named QCS (Quality Control Service). QCS is a combination of internal and external quality control. Both procedures use the same data getting from analyzers. In this scheme Roche considered the problem of matrix effect. Matrix effect is the difference between a human sample and the corresponding control sample. Purpose: The detection of matrix effect and the institution of corrective actions in order to prevent this phenomenon on the future. Material - Method: As experimental materials were used the QCS’s control samples (PCU QCS 10651257/922 and PCTM QCS 10651265/922). These control specimens (PreciControls) were analyzed on the analyzers Roche/Hitachi Elecsys 1010 and 2010. Both analyzers use the technology of electrochemiluminescense and they measure a large variety analytes. The statistical analysis and storage were done with the use of program QCS Easy 4. Results: Statistical important differences were found between the results of human and control samples. These findings reveal the following: Roche determine its analytes on PreciControls as well as on human serum pools. These pools are stored in such conditions that retain their substances steady for a long time. On the other hand Roche determine the consensus mean of PreciControls before their posting to its customers. Although PreciControls are analyzed in referral laboratories, Roche noticed differences when different reagent’s lots were used for the determination of the same PreciControl’s lot. There is no any similar difference between different reagent’s lots and the same human pool. Discusion: The explanation of these differences lies in the matrix effect. It seems that the conservatives and the additives which are added in the serum change the protein structure, especially the antigen chemical affinity. Conclusion: Because of the matrix effect Roche proposes that the interlaboratory comparisons must refer not only in a certain control serum but in a combination of control serum and reagent lot. en
heal.publisher Balkan Clinical Laboratory Federation en
heal.fullTextAvailability false
heal.conferenceName 15th Balkan Conference of Clinical Chemistry en
heal.conferenceItemType abstract


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες