dc.contributor.author | Κανδαράκης, Ιωάννης Σ. | el |
dc.contributor.author | Κάβουρας, Διονύσης Α. | el |
dc.contributor.author | Παναγιωτάκης, Γεώργιος Σ. | el |
dc.contributor.author | Αγγέλης, Τ. | el |
dc.contributor.author | Νομικός, Κωνσταντίνος Δ. | el |
dc.date.accessioned | 2015-05-04T08:35:46Z | |
dc.date.available | 2015-05-04T08:35:46Z | |
dc.date.issued | 2015-05-04 | |
dc.identifier.uri | http://hdl.handle.net/11400/9614 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://iopscience.iop.org/0031-9155/41/2/007 | en |
dc.subject | Phosphor screens | |
dc.subject | Data | |
dc.subject | Οθόνες φωσφόρου | |
dc.subject | Δεδομένα | |
dc.title | X-ray induced luminescence and spatial resolution of La2O2S:Tb phosphor screens | en |
heal.type | journalArticle | |
heal.classification | Medicine | |
heal.classification | Physics | |
heal.classification | Ιατρική | |
heal.classification | Φυσική | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://skos.um.es/unescothes/C02994 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Φυσική | |
heal.contributorName | Γιακουμάκης, Γ. | el |
heal.identifier.secondary | doi:10.1088/0031-9155/41/2/007 | |
heal.language | en | |
heal.access | campus | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 1996 | |
heal.bibliographicCitation | Kandarakis, I., Cavouras, D., Panayiotakis, G., Agelis, T., Nomicos, C., et al. (February 1996). X-ray induced luminescence and spatial resolution of La2O2S:Tb phosphor screens. Physics in Medicine and Biology. 41(2). pp. 297-307. IOP Publishing: 1996. Available from: http://iopscience.iop.org/0031-9155/41/2/007 | en |
heal.abstract | Absolute efficiency and modulation transfer function of laboratory prepared phosphor screens of various coating thickness were studied. Detailed experimental data on the variation of absolute efficiency with x-ray tube voltage up to 200 kVp and screen coating thickness in transmission and reflection observation mode are given. Data were compared with similar results from other rare earth phosphor materials. Theoretical calculations were in good agreement with experimental data to permit estimation of intrinsic efficiency and coefficients related to light scattering and absorption within the phosphor material. The MTF of screens was also experimentally and theoretically evaluated. | en |
heal.publisher | IOP Publishing | en |
heal.journalName | Physics in Medicine and Biology | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: