dc.source http://www.sciencedirect.com/science/article/pii/S0168900297009558 en
dc.subject Imaging scintillators
dc.subject Medical imaging
dc.subject Σπινθηριστές απεικόνισης
dc.subject Ιατρική απεικόνιση
dc.title An experimental method for the determination of spatial frequency dependent detective quantum efficiency (DQE) of scintillators used in x-ray imaging detectors en
heal.type journalArticle
heal.classification Medicine
heal.classification Physics
heal.classification Ιατρική
heal.classification Φυσική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://skos.um.es/unescothes/C02994
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Φυσική
heal.identifier.secondary doi:10.1016/S0168-9002(97)00955-8
heal.language en
heal.access campus
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 1997
heal.bibliographicCitation Kandarakis, I., Cavouras, D., Panayiotakis, G., Triantis, D. and Nomicos, C. (November 1997). An experimental method for the determination of spatial frequency dependent detective quantum efficiency (DQE) of scintillators used in x-ray imaging detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 399(2-3). pp. 335-342. Elsevier B.V: 1997. Available from: http://www.sciencedirect.com/science/article/pii/S0168900297009558 [Accessed 17/05/1998] en
heal.abstract The spatial-frequency-dependent detective quantum efficiency (DQE) of imaging scintillators was studied independently of the optical detector (film, photocathode, or photodiode) employed in medical imaging devices. A method was developed to experimentally determine the scintillator DQE in terms of its luminescence efficiency (LE), quantum detection efficiency, modulation transfer function, and light emission spectrum. Gd2O2S : Tb, La2O2S : Tb, Y2O2S : Tb and ZnSCdS : Ag scintillating screens were prepared in laboratory and were excited to luminescence by a medical X-ray tube. Maximum DQE values varied between 0.13 and 0.33 depending on the scintillator material, the screen coating weight, and the tube voltage; Gd2O2S : Tb was superior to La2O2S : Tb followed by ZnSCdS : Ag and Y2O2S : Tb. This ranking was maintained at frequencies up to 100 cycles/cm. Considering the same material, DQE of thin screens was found superior to DQE of thicker screens at medium-to-high frequencies. The proposed method allows for the comparison of imaging characteristics of scintillating materials without the inclusion of optical detector imaging properties. en
heal.publisher Elsevier B.V. en
heal.journalName Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: An experimental method for the ...
    Μέγεθος: 634.6Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες