dc.contributor.author | Κανδαράκης, Ιωάννης Σ. | el |
dc.contributor.author | Κάβουρας, Διονύσης Α. | el |
dc.contributor.author | Παναγιωτάκης, Γεώργιος Σ. | el |
dc.contributor.author | Τριάντης, Δήμος Α. | el |
dc.contributor.author | Νομικός, Κωνσταντίνος Δ. | el |
dc.date.accessioned | 2015-05-04T10:01:09Z | |
dc.date.available | 2015-05-04T10:01:09Z | |
dc.date.issued | 2015-05-04 | |
dc.identifier.uri | http://hdl.handle.net/11400/9629 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://www.sciencedirect.com/science/article/pii/S0168900297009558 | en |
dc.subject | Imaging scintillators | |
dc.subject | Medical imaging | |
dc.subject | Σπινθηριστές απεικόνισης | |
dc.subject | Ιατρική απεικόνιση | |
dc.title | An experimental method for the determination of spatial frequency dependent detective quantum efficiency (DQE) of scintillators used in x-ray imaging detectors | en |
heal.type | journalArticle | |
heal.classification | Medicine | |
heal.classification | Physics | |
heal.classification | Ιατρική | |
heal.classification | Φυσική | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://skos.um.es/unescothes/C02994 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Φυσική | |
heal.identifier.secondary | doi:10.1016/S0168-9002(97)00955-8 | |
heal.language | en | |
heal.access | campus | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 1997 | |
heal.bibliographicCitation | Kandarakis, I., Cavouras, D., Panayiotakis, G., Triantis, D. and Nomicos, C. (November 1997). An experimental method for the determination of spatial frequency dependent detective quantum efficiency (DQE) of scintillators used in x-ray imaging detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 399(2-3). pp. 335-342. Elsevier B.V: 1997. Available from: http://www.sciencedirect.com/science/article/pii/S0168900297009558 [Accessed 17/05/1998] | en |
heal.abstract | The spatial-frequency-dependent detective quantum efficiency (DQE) of imaging scintillators was studied independently of the optical detector (film, photocathode, or photodiode) employed in medical imaging devices. A method was developed to experimentally determine the scintillator DQE in terms of its luminescence efficiency (LE), quantum detection efficiency, modulation transfer function, and light emission spectrum. Gd2O2S : Tb, La2O2S : Tb, Y2O2S : Tb and ZnSCdS : Ag scintillating screens were prepared in laboratory and were excited to luminescence by a medical X-ray tube. Maximum DQE values varied between 0.13 and 0.33 depending on the scintillator material, the screen coating weight, and the tube voltage; Gd2O2S : Tb was superior to La2O2S : Tb followed by ZnSCdS : Ag and Y2O2S : Tb. This ranking was maintained at frequencies up to 100 cycles/cm. Considering the same material, DQE of thin screens was found superior to DQE of thicker screens at medium-to-high frequencies. The proposed method allows for the comparison of imaging characteristics of scintillating materials without the inclusion of optical detector imaging properties. | en |
heal.publisher | Elsevier B.V. | en |
heal.journalName | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: