dc.contributor.author | Κάβουρας, Διονύσης Α. | el |
dc.contributor.author | Κανδαράκης, Ιωάννης Σ. | el |
dc.contributor.author | Παναγιωτάκης, Γεώργιος Σ. | el |
dc.contributor.author | Μπάκας, Αθανάσιος | el |
dc.contributor.author | Τριάντης, Δήμος Α. | el |
dc.date.accessioned | 2015-05-04T10:32:37Z | |
dc.date.issued | 2015-05-04 | |
dc.identifier.uri | http://hdl.handle.net/11400/9637 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://www.birpublications.org/doi/abs/10.1259/bjr.71.847.9771388 | en |
dc.subject | X-ray imaging applications | |
dc.subject | Photodetectors | |
dc.subject | Εφαρμογές απεικόνισης ακτίνων Χ | |
dc.subject | Φωτοανιχνευτές | |
dc.title | An experimental method to determine the effective efficiency of scintillator-photodetector combinations used in x-ray medical imaging systems | en |
heal.type | journalArticle | |
heal.classification | Medicine | |
heal.classification | Physics | |
heal.classification | Ιατρική | |
heal.classification | Φυσική | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://skos.um.es/unescothes/C02994 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Φυσική | |
heal.contributorName | Νομικός, Κωνσταντίνος Δ. | el |
heal.identifier.secondary | DOI: http://dx.doi.org/10.1259/bjr.71.847.9771388 | |
heal.dateAvailable | 10000-01-01 | |
heal.language | en | |
heal.access | forever | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 1998 | |
heal.bibliographicCitation | Cavouras, D., Kandarakis, I., Panayiotakis, G., Bakas, A., Triantis, D., et al. (1998). An experimental method to determine the effective efficiency of scintillator-photodetector combinations used in x-ray medical imaging systems. British Journal of Radiology. 71(847). pp. 766-772. British Institute of Radiology: 1998. | en |
heal.abstract | The scintillator effective luminescence efficiency, which may be defined in terms of the scintillator's X-ray luminescence efficiency and the scintillator-photodetector spectral matching and geometrical configuration, was studied for various X-ray imaging applications. Four scintillator materials Gd2O2S:Tb, Y2O2S:Tb, ZnSCdS:Ag and CsI:Na were used to prepare test screens. They were evaluated in relation to various photodetectors used in X-ray imaging, such as radiographic films, photocathodes, and photodiodes. Effective luminescence efficiency was determined for a range of X-ray tube voltages (50-140 kVp) by measuring the light flux emitted per unit of incident exposure rate and the spectra of the light emitted by the four scintillators. Scintillator-photodetector combinations resulting in higher image brightness level were determined for different X-ray imaging systems. Findings indicate that CsI:Na is very efficient with orthochromatic radiographic films, Gd2O2S:Tb could be useful in conventional or digital fluoroscopy and in CT and ZnSCdS:Ag could be employed in some medium to low voltage digital radiography applications. | en |
heal.publisher | British Institute of Radiology | en |
heal.journalName | British Journal of Radiology | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | false |
Αρχεία | Μέγεθος | Μορφότυπο | Προβολή |
---|---|---|---|
Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο. |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: