Εμφάνιση απλής εγγραφής

dc.contributor.author Κανδαράκης, Ιωάννης Σ. el
dc.contributor.author Κάβουρας, Διονύσης Α. el
dc.contributor.author Πρασόπουλος, Παναγιώτης Π. el
dc.contributor.author Κανελλόπουλος, Ε. el
dc.contributor.author Νομικός, Κωνσταντίνος Δ. el
dc.date.accessioned 2015-05-05T09:09:26Z
dc.date.available 2015-05-05T09:09:26Z
dc.date.issued 2015-05-05
dc.identifier.uri http://hdl.handle.net/11400/9721
dc.rights An error occurred on the license name. *
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri An error occurred getting the license - uri. *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.ejradiology.com/article/S0720-048X(98)00109-0/abstract en
dc.subject Scintillators
dc.subject X-ray luminescence
dc.subject Σπινθηριστές
dc.subject X-ray φωταύγεια
dc.title Evaluating scintillators used in radiation detectors of medical imaging systems by the effective fidelity index (EFI) method en
heal.type journalArticle
heal.classification Medicine
heal.classification Physics
heal.classification Ιατρική
heal.classification Φυσική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://skos.um.es/unescothes/C02994
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Φυσική
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85118713
heal.contributorName Παναγιωτάκης, Γεώργιος Σ. el
heal.identifier.secondary DOI: http://dx.doi.org/10.1016/S0720-048X(98)00109-0
heal.language en
heal.access campus
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 1999
heal.bibliographicCitation Kandarakis, I., Cavouras, D., Prassopoulos, P., Kanellopoulos, E., Nomicos, C., et al. (April 1999). Evaluating scintillators used in radiation detectors of medical imaging systems by the effective fidelity index (EFI) method. European Journal of Radiology. 30(1). pp. 61-66. Elsevier Inc: 1999. Available from: http://www.ejradiology.com/article/S0720-048X(98)00109-0/abstract en
heal.abstract Objective: The performance of medical X-ray image receptors depends: (1) on the scintillator light emission efficiency; and (2) on the compatibility of the scintillator light spectrum with the spectral sensitivity of the light detector (film, photocathode, or photodiode), employed in conjunction with the scintillator. In this study, a scintillator performance measure, the effective fidelity index (EFI), is defined as function of both the scintillator light emission efficiency and spectral compatibility. Materials and Method: CsI:Na, Gd2O2S:Tb and La2O2S:Tb scintillators were employed in the form of phosphor screens prepared in our laboratory with various coating thicknesses. The screens were irradiated with X-rays employing tube voltages ranging between 50–120 kVp. Results: The EFI performance of CsI:Na was found to increase with screen coating thickness and it was best when combined with the orthochromatic film or the ES/20 photocathode. Gd2O2S:Tb showed peak EFI performance at 70 mg/cm2 coating thickness and it was well combined with the light detectors considered. Conclusion: In accordance with our results, CsI:Na may be employed in radiography when adequately protected against humidity. Gd2O2S:Tb suitability for conventional imaging was verified and it was found that it may be useful in all types of digital imaging. La2O2S:Tb could also be used in digital detectors of imaging applications demanding medium X-ray tube voltages. en
heal.publisher Elsevier Inc en
heal.journalName European Journal of Radiology en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: Evaluating scintillators used ...
    Μέγεθος: 222.7Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής