Εμφάνιση απλής εγγραφής

dc.contributor.author Κάβουρας, Διονύσης Α. el
dc.contributor.author Κανδαράκης, Ιωάννης Σ. el
dc.contributor.author Κανελλόπουλος, Μ. el
dc.contributor.author Νομικός, Κωνσταντίνος Δ. el
dc.contributor.author Παναγιωτάκης, Γεώργιος Σ. el
dc.date.accessioned 2015-05-05T09:28:29Z
dc.date.available 2015-05-05T09:28:29Z
dc.date.issued 2015-05-05
dc.identifier.uri http://hdl.handle.net/11400/9724
dc.rights An error occurred on the license name. *
dc.rights.uri An error occurred getting the license - uri. *
dc.source http://www.sciencedirect.com/science/article/pii/S0969804398001365 en
dc.subject Scintillators
dc.subject Light photon energy
dc.subject Σπινθηριστές
dc.subject Φωτεινή ενέργεια φωτονίων
dc.title Signal-to-noise-ratio (SNR) of X-ray imaging scintillators determined by luminescence measurements en
heal.type journalArticle
heal.classification Medicine
heal.classification Physics
heal.classification Ιατρική
heal.classification Φυσική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://skos.um.es/unescothes/C02994
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Φυσική
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85118713
heal.identifier.secondary doi:10.1016/S0969-8043(98)00136-5
heal.language en
heal.access campus
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 1999
heal.bibliographicCitation Cavouras, D., Kandarakis, I., Kanellopoulos, M., Nomicos, C. and Panayiotakis, G. (July 1999). Signal to Noise Ratio (SNR) of x-ray imaging scintillators determined by luminescence measurements. Applied Radiation and Isotopes. 51(1). pp. 59-68. Elsevier Science Ltd: 1999. Available from: http://www.sciencedirect.com/science/article/pii/S0969804398001365 [Accessed 25/05/1999] en
heal.abstract A new method for studying the signal-to-noise-ratio (SNR) of X-ray imaging scintillators was developed. SNR was expressed in terms of the X-ray luminescence efficiency (XLE) the X-ray to emitted light conversion efficiency and the mean light photon energy. Laboratory prepared Gd2O2S:Tb, La2O2S:Tb and Y2O2S:Tb scintillator screens were tested and best results were obtained for the 80 mg/cm2 Gd2O2S:Tb screen. The method proposed allows for scintillator comparison on the basis of XLE and wavelength measurements. en
heal.publisher Elsevier Science Ltd en
heal.journalName Applied Radiation and Isotopes en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: Signal to Noise Ratio (SNR) of ...
    Μέγεθος: 534.2Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής