dc.contributor.author | Κάβουρας, Διονύσης Α. | el |
dc.contributor.author | Κανδαράκης, Ιωάννης Σ. | el |
dc.contributor.author | Νομικός, Κωνσταντίνος Δ. | el |
dc.contributor.author | Μπάκας, Αθανάσιος | el |
dc.contributor.author | Παναγιωτάκης, Γεώργιος Σ. | el |
dc.date.accessioned | 2015-05-05T10:40:30Z | |
dc.date.available | 2015-05-05T10:40:30Z | |
dc.date.issued | 2015-05-05 | |
dc.identifier.uri | http://hdl.handle.net/11400/9731 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://www.sciencedirect.com/science/article/pii/S1350448799002450 | en |
dc.subject | Phosphors | |
dc.subject | Medical imaging applications | |
dc.subject | Φώσφορος | |
dc.subject | Ιατρικές εφαρμογές απεικόνισης | |
dc.title | Measurement of the (Gd,La)2O2S:Tb phosphor efficiency for x-ray imaging applications | en |
heal.type | journalArticle | |
heal.classification | Science | |
heal.classification | Physics | |
heal.classification | Επιστήμες | |
heal.classification | Φυσική | |
heal.classificationURI | http://skos.um.es/unescothes/C03532 | |
heal.classificationURI | http://skos.um.es/unescothes/C02994 | |
heal.classificationURI | **N/A**-Επιστήμες | |
heal.classificationURI | **N/A**-Φυσική | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh85101117 | |
heal.identifier.secondary | doi:10.1016/S1350-4487(99)00245-0 | |
heal.language | en | |
heal.access | campus | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 2000 | |
heal.bibliographicCitation | Cavouras, D., Kandarakis, I., Nomicos, C., Bakas, A. and Panayiotakis, G. (February 2000). Measurement of the (Gd,La)2O2S:Tb phosphor efficiency for x-ray imaging applications. Radiation Measurements. 32(1). pp. 5-13. Elsevier Ireland Ltd: 2000. Available from: http://www.sciencedirect.com/science/article/pii/S1350448799002450 [Accessed 09/12/1999] | en |
heal.abstract | Gd,La)2O2S:Tb phosphor performance was tested under x-ray excitation for medical imaging applications with tube voltages from 70 to 180 kVp and phosphor coating weights from 20 to 240 mg/cm2. The emission spectrum of (Gd,La)2O2S:Tb was also measured and it was centered at 549 nm. (Gd,La)2O2S:Tb was found efficient in a wide range of x-ray tube voltages and adequately compatible with photocathodes, photodiodes, and orthochromatic films currently used in x-ray medical imaging. | en |
heal.publisher | Elsevier Ireland Ltd | en |
heal.journalName | Radiation Measurements | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |