Εμφάνιση απλής εγγραφής

dc.contributor.author Κάβουρας, Διονύσης Α. el
dc.contributor.author Κανδαράκης, Ιωάννης Σ. el
dc.contributor.author Νομικός, Κωνσταντίνος Δ. el
dc.contributor.author Παναγιωτάκης, Γεώργιος Σ. el
dc.contributor.author Φεζουλίδης, Ιωάννης Β. el
dc.date.accessioned 2015-05-05T11:18:07Z
dc.date.available 2015-05-05T11:18:07Z
dc.date.issued 2015-05-05
dc.identifier.uri http://hdl.handle.net/11400/9734
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.sciencedirect.com/science/article/pii/S0969804399001165 en
dc.subject Medical phosphors
dc.subject Phosphoro screens
dc.subject Ιατρική φωσφορίζουσες
dc.subject Οθόνες φωσφόρου
dc.title Assessing the information content of phosphor produced medical images en
heal.type journalArticle
heal.secondaryTitle application to Zn2SiO4:Mn phosphor en
heal.classification Medicine
heal.classification Physics
heal.classification Ιατρική
heal.classification Φυσική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://skos.um.es/unescothes/C02994
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Φυσική
heal.identifier.secondary doi:10.1016/S0969-8043(99)00116-5
heal.language en
heal.access campus
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2000
heal.bibliographicCitation Cavouras, D., Kandarakis, I., Nomicos, C., Panayiotakis, G. and Fezoulidis, I. (January 2000). Assessing the information content of phosphor produced medical images: application to Zn2SiO4:Mn phosphor. Applied Radiation and Isotopes. 52(1). pp. 119-126. Elsevier Science Ltd: 2000. Available from: http://www.sciencedirect.com/science/article/pii/S0969804399001165 [Accessed 09/12/1999] en
heal.abstract In this study a method to assess the information content of medical images produced by phosphors is described. The optical signal emitted by the phosphor after X-ray excitation, the detective quantum efficiency (DQE), expressing the signal-to-noise ratio (SNR) transfer efficiency, and the information capacity were experimentally determined. The method was based on light flux and modulation transfer function (MTF) measurements and was used to assess the imaging performance of the Zn2SiO4:Mn phosphor. The latter was employed in the form of laboratory prepared phosphor layers (test screens). Results showed that high values for optical signal emission and DQE were obtained for medium thickness phosphor layers (56 and 89 mg/cm2) at 20 kVp X-ray tube voltage. The information capacity was found to decrease continuously with phosphor coating weight. en
heal.publisher Elsevier Science Ltd en
heal.journalName Applied Radiation and Isotopes en
heal.journalType peer-reviewed
heal.fullTextAvailability true