Εμφάνιση απλής εγγραφής

dc.contributor.author Κάβουρας, Διονύσης Α. el
dc.contributor.author Κανδαράκης, Ιωάννης Σ. el
dc.contributor.author Μαρής, Θωμάς el
dc.contributor.author Παναγιωτάκης, Γεώργιος Σ. el
dc.contributor.author Νομικός, Κωνσταντίνος Δ. el
dc.date.accessioned 2015-05-05T11:32:26Z
dc.date.available 2015-05-05T11:32:26Z
dc.date.issued 2015-05-05
dc.identifier.uri http://hdl.handle.net/11400/9735
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.ejradiology.com/article/S0720-048X(99)00106-0/abstract en
dc.source http://www.sciencedirect.com/science/article/pii/S0720048X99001060 en
dc.subject Phosphors
dc.subject Spectral compatibility
dc.subject Φωσφορίζουσες
dc.subject Φασματική συμβατότητα
dc.title Assessment of the gain transfer function (GTF) of phosphors for application in medical imaging radiation detectors el
heal.type journalArticle
heal.classification Medicine
heal.classification Physics
heal.classification Ιατρική
heal.classification Φυσική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://skos.um.es/unescothes/C02994
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Φυσική
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85101117
heal.identifier.secondary DOI: http://dx.doi.org/10.1016/S0720-048X(99)00106-0
heal.language en
heal.access campus
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2000
heal.bibliographicCitation Cavouras, D., Kandarakis, I., Maris, T., Panayiotakis, G. and Nomicos, C. (July 2000). Assessment of the gain transfer function (GTF) of phosphors for application in medical imaging radiation detectors. European Journal of Radiology. 35(1). pp. 70-77. Elsevier: 2000. Available from: http://www.sciencedirect.com/science/article/pii/S0720048X99001060 [Accessed 03/08/2000] en
heal.abstract Objective: to study various phosphors used in detectors of medical imaging systems by the gain transfer function (GTF), defined in terms of X-ray luminescence efficiency, light spectrum and modulation transfer function. Materials and methods: four phosphor materials, La2O2S:Tb, Y2O2S:Tb, Y2O2S:Eu and Y2O3:Eu were used in the form of fluorescent layers prepared in the laboratory. The GTF was determined at 30 kVp and 80 kVp X-ray tube voltages for various phosphor coating weights. Results: La2O2S:Tb, which was the highest density and effective atomic number phosphor used, was found to exhibit the best GTF performance at 80 kVp. At 30 kVp, the yttrium based phosphors were found of increased performance. This is mainly due to the proximity of the X-ray energy to the K-absorption edge of yttrium at 17 keV. Europium activated phosphors were found to perform very well when combined with the red sensitive film and the silicon photodiode. Conclusion: The GTF may be a useful method for comparing and selecting phosphor materials for use in various medical imaging applications. en
heal.publisher Elsevier en
heal.journalName European Journal of Radiology en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: Assessment of the gain transfer ...
    Μέγεθος: 234.5Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες