Εμφάνιση απλής εγγραφής

dc.contributor.author Κάβουρας, Διονύσης Α. el
dc.contributor.author Κανδαράκης, Ιωάννης Σ. el
dc.contributor.author Παναγιωτάκης, Γεώργιος Σ. el
dc.contributor.author Νομικός, Κωνσταντίνος Δ. el
dc.date.accessioned 2015-05-05T12:49:12Z
dc.date.available 2015-05-05T12:49:12Z
dc.date.issued 2015-05-05
dc.identifier.uri http://hdl.handle.net/11400/9742
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://link.springer.com/article/10.1007%2FBF02344207 en
dc.subject X-ray imaging
dc.subject Information capacity
dc.subject Απεικόνιση με ακτίνες Χ
dc.subject Πληροφοριακή ικανότητα
dc.title Integrated model for estimating phosphor signal and noise transfer characteristics on medical images en
heal.type journalArticle
heal.secondaryTitle application to CdPO3Cl:Mn phosphor screens en
heal.classification Science
heal.classification Physics
heal.classification Επιστήμες
heal.classification Φυσική
heal.classificationURI http://skos.um.es/unescothes/C03532
heal.classificationURI http://skos.um.es/unescothes/C02994
heal.classificationURI **N/A**-Επιστήμες
heal.classificationURI **N/A**-Φυσική
heal.identifier.secondary DOI 10.1007/BF02344207
heal.language en
heal.access campus
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2002
heal.bibliographicCitation Cavouras, D., Kandarakis, I., Panayiotakis, G. and Nomicos C. (2002). Integrated model for estimating phosphor signal and noise transfer characteristics on medical images: application to CdPO3Cl:Mn phosphor screens. Medical and Biological Engineering and Computing. 40(3). pp. 273-277. Springer-Verlag: 2002. Available from: http://link.springer.com/article/10.1007%2FBF02344207 en
heal.abstract An integrated model describing the signal and noise transfer characteristics of the objective image quality and information content in phosphor-produced images is presented. In the context of this model, important imaging parameters, namely optical gain, modulation transfer function, noise transfer function, detective quantum efficiency and information capacity were experimentally evaluated using seven laboratory-prepared CdPO3Cl:Mn test phosphor screens of varying coating thickness. This phosphor has been previously shown to exhibit high spectral compatibility properties with the films and optical sensors used in digital imaging systems. Experiments were performed using 50–120 kVp X-rays produced by a medical X-ray unit. Results showed that, for thick screens, optical gain attained peak values close to 200 optical photons per incident X-ray at 50 kVp. The noise transfer function was higher than the modulation transfer function. For the thin screen of 21 mgcm−2, the modulation transfer function was 0.25 at 100 line pairs mm−1, and the corresponding noise transfer function was 0.4. The detection quantum efficiency peak value was 0.22 at 50 kVp. These values are within acceptable performance limits, and, given the phosphor material's high spectral compatibility and medium temporal response, CdPO3Cl:Mn could be considered for use in X-ray detectors of static radiography imaging. en
heal.publisher Springer-Verlag en
heal.journalName Medical and Biological Engineering and Computing en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: Integrated model for estimating ...
    Μέγεθος: 606.3Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες