dc.contributor.author | Κανδαράκης, Ιωάννης Σ. | el |
dc.contributor.author | Κάβουρας, Διονύσης Α. | el |
dc.contributor.author | Νικολόπουλος, Δημήτριος Σ. | el |
dc.contributor.author | Επισκοπάκης, Α. | el |
dc.contributor.author | Καλύβας, Νεκτάριος Ι. | el |
dc.date.accessioned | 2015-05-07T17:29:56Z | |
dc.date.available | 2015-05-07T17:29:56Z | |
dc.date.issued | 2015-05-07 | |
dc.identifier.uri | http://hdl.handle.net/11400/9863 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://www.sciencedirect.com/science/article/pii/S0969804305003726 | en |
dc.subject | Scintillators | |
dc.subject | Luminescence | |
dc.subject | Σπινθηριστές | |
dc.subject | Φωτοβολία | |
dc.title | A theoretical model evaluating the angular distribution of luminescence emission in X-ray scintillating screens | en |
heal.type | journalArticle | |
heal.classification | Science | |
heal.classification | Physics | |
heal.classification | Επιστήμες | |
heal.classification | Φυσική | |
heal.classificationURI | http://skos.um.es/unescothes/C03532 | |
heal.classificationURI | http://skos.um.es/unescothes/C02994 | |
heal.classificationURI | **N/A**-Επιστήμες | |
heal.classificationURI | **N/A**-Φυσική | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh85118713 | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh85078838 | |
heal.contributorName | Λιαπαρινός, Παναγιώτης Φ. | el |
heal.contributorName | Βαλαής, Ιωάννης Γ. | el |
heal.contributorName | Καγκάδης, Γεώργιος Χ. | el |
heal.contributorName | Κουρκουτάς, Κωνσταντίνος Δ. | el |
heal.contributorName | Σιανούδης, Ιωάννης Α. | el |
heal.contributorName | Δημητρόπουλος, Νικόλαος | el |
heal.contributorName | Νομικός, Κωνσταντίνος Δ. | el |
heal.contributorName | Παναγιωτάκης, Γεώργιος Σ. | el |
heal.identifier.secondary | doi:10.1016/j.apradiso.2005.11.016 | |
heal.language | en | |
heal.access | campus | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 2006 | |
heal.bibliographicCitation | Kandarakis, I., Cavouras, D., Nikolopoulos, D., Episkopakis, A., Kalivas, N., et al. (April 2006). A theoretical model evaluating the angular distribution of luminescence emission in X-ray scintillating screens. Applied Radiation and Isotopes. 64(4). pp. 508-519. Elsevier Ltd: 2006. Available from: http://www.sciencedirect.com/science/article/pii/S0969804305003726 [Accessed 04/01/2006] | en |
heal.abstract | The aim of this study was to examine the angular distribution of the light emitted from radiation-excited scintillators in medical imaging detectors. This distribution diverges from Lambert's cosine law and affects the light emission efficiency of scintillators, hence it also affects the dose burden to the patient. In the present study, the angular distribution was theoretically modeled and was used to fit experimental data on various scintillator materials. Results of calculations revealed that the angular distribution is more directional than that predicted by Lambert's law. Divergence from this law is more pronounced for high values of light attenuation coefficient and thick scintillator layers (screens). This type of divergence reduces light emission efficiency and hence it increases the incident X-ray flux required for a given level of image brightness. | en |
heal.publisher | Elsevier Ltd | en |
heal.journalName | Applied Radiation and Isotopes | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: