dc.subject | Line spread function | |
dc.subject | Modulation transfer function | |
dc.subject | Λειτουργία εξάπλωσης γραμμής | |
dc.subject | Λειτουργία Modulation Transfer | |
dc.title | The use of the modulation transfer function for comparison and image quality asseeement of commercially available hytbrid PET-CT scanners | en |
heal.type | conferenceItem | |
heal.generalDescription | Proceedings | en |
heal.classification | Technology | |
heal.classification | Biomedical engineering | |
heal.classification | Τεχνολογία | |
heal.classification | Βιοϊατρική τεχνολογία | |
heal.classificationURI | http://zbw.eu/stw/descriptor/10470-6 | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh85014237 | |
heal.classificationURI | **N/A**-Τεχνολογία | |
heal.classificationURI | **N/A**-Βιοϊατρική τεχνολογία | |
heal.contributorName | Κουνάδη, Ευαγγελία | el |
heal.contributorName | Παπασπύρου, Λ. | el |
heal.contributorName | Κανδαράκης, Ιωάννης Σ. | el |
heal.contributorName | Νικηφορίδης, Γεώργιος Χ. | el |
heal.identifier.secondary | 10.1594/ecr2010/C-2943 | |
heal.dateAvailable | 10000-01-01 | |
heal.language | en | |
heal.access | forever | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 2010 | |
heal.bibliographicCitation | Samartzism A., Kalatzis, I., Fountos, G., Cavouras, D., Datseris, I., et al. (2010). The use of the modulation transfer function for comparison and image quality asseeement of commercially available hytbrid PET-CT scanners. Proceeding of the European Congress of Radiology (ECR) 2010. Vienna, Austria, 4th-8th March 2010. | en |
heal.abstract | Aim of our study was to implement a new method for the determination of the Modulation Transfer Function (MTF) in order to evaluate the performance of hybrid PET - CT systems, with a fast and low cost method, based on easily accessible materials to the physicist in the hospital. The key to this approach was the preparation of a novel and highly homogeneous - high activity film flood source, using Fluorine18 as the positrons emitting nuclide. | en |
heal.fullTextAvailability | true | |
heal.conferenceName | European Congress of Radiology | en |
heal.conferenceItemType | full paper |