dc.contributor.author | Γκουρτσογιάννης, Νικόλαος | el |
dc.contributor.author | Πρασόπουλος, Παναγιώτης Π. | el |
dc.contributor.author | Κάβουρας, Διονύσης Α. | el |
dc.contributor.author | Παντελίδης, Ν. | el |
dc.date.accessioned | 2015-05-07T17:33:20Z | |
dc.date.available | 2015-05-07T17:33:20Z | |
dc.date.issued | 2015-05-07 | |
dc.identifier.uri | http://hdl.handle.net/11400/9869 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://www.ajronline.org/doi/abs/10.2214/ajr.155.3.2117353 | en |
dc.subject | Renal parenchymal thickness | |
dc.subject | Patient | |
dc.subject | Νεφρικό πάχος του παρεγχύματος | |
dc.subject | Ασθενής | |
dc.title | The thickness of the renal parenchyma decreases with age | en |
heal.type | journalArticle | |
heal.secondaryTitle | a CT study of 360 patients | en |
heal.classification | Medicine | |
heal.classification | Biomedical engineering | |
heal.classification | Ιατρική | |
heal.classification | Βιοϊατρική τεχνολογία | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh85014237 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Βιοϊατρική τεχνολογία | |
heal.language | el | |
heal.access | campus | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 1990 | |
heal.bibliographicCitation | Gourtsoyiannis, N., Prassopoulos, P., Cavouras, D. and Pantelidis, N. (September 1990). The thickness of the renal parenchyma decreases with age: a CT study of 360 patients. American Journal Roentgenology. 155(3). pp. 541-544. American Roentgen Ray Society: 1990. Available from: http://www.ajronline.org/doi/abs/10.2214/ajr.155.3.2117353 | en |
heal.abstract | Renal parenchymal thickness was estimated by using CT in 360 patients with no evidence of renal disease. In each patient, the measurements were normalized to the transverse diameter of the vertebral body and a reference table was formulated. The renal parenchymal thickness decreases about 10% per decade of increasing age in both men and women. These findings are consistent with previously reported findings based on autopsy material. The proposed table may be useful as a criterion for assessing normal renal parenchyma on CT. | en |
heal.publisher | American Roentgen Ray Society | en |
heal.journalName | American Journal of Roentgenology | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: