dc.contributor.author | Παπαδάς, Γιώργος | el |
dc.contributor.author | Σινάνογλου, Βασιλεία | el |
dc.contributor.author | Μηνιάδου - Μεϊμάρογλου, Σοφία | el |
dc.date.accessioned | 2015-06-02T17:30:11Z | |
dc.date.issued | 2015-06-02 | |
dc.identifier.uri | http://hdl.handle.net/11400/14881 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://www.eurofedlipid.org/ | en |
dc.subject | Λιπίδια | |
dc.subject | Ιονισμός | |
dc.subject | Ψάρια | |
dc.subject | Fish | |
dc.subject | Χρωμογραφική ανάλυση | |
dc.title | Separation and quantification of marine lipids using Iatroscan thin-layer chromatographic-flame ionisation detection analysis | en |
heal.type | conferenceItem | |
heal.classification | Food | |
heal.classification | Food technology | |
heal.classification | Τροφή | |
heal.classification | Τεχνολογία τροφίμων | |
heal.classificationURI | http://id.loc.gov/authorities/names/n00009376 | |
heal.classificationURI | http://skos.um.es/unescothes/C01577 | |
heal.classificationURI | **N/A**-Τροφή | |
heal.classificationURI | **N/A**-Τεχνολογία τροφίμων | |
heal.dateAvailable | 10000-01-01 | |
heal.language | en | |
heal.access | forever | |
heal.publicationDate | 2008-09-07 | |
heal.bibliographicCitation | Papadas, G., Sinanoglou, V. and Miniadis-Meimaroglou, S. (2008) Separation and quantification of marine lipids using Iatroscan thin-layer chromatographic–flame ionisation detection analysis. In 6th Euro Fed Lipid Congress: Oils, Fats and Lipids in the 3rd Millennium. 7th to 10th September 2008. Athens | en |
heal.abstract | A method for separation and quantification of neutral lipid and phospholipid classes was developed using Iatroscan analysis, which combines thin layer chromatography (TLC) and flame ionisation detection (FID) techniques. Neutral lipid classes were developed and separated in several solvent systems with hexane-diethyl ether-formic acid (H:D:F). Phospholipid classes were developed and separated in several solvent systems with chloroform-methanol-water (C:M:W), chloroform-methanol-water-formic acid (C:M:W:F) and chloroform-methanol-water-ammonia (C:M:W:A). Finally, neutral lipid and phospholipid classes were developed and separated by several multiple developments using 2 or 3 different development solvent systems of decreasing polarity. The bath temperature was 25oC. The measurement conditions were hydrogen flow-rate 160 mL/min, air flow-rate 2L/min and scan speed 30s/scan. Even a slight difference in solvent proportion or composition of development solution influenced the chromatogram pattern as well as the individual lipid classes’ fractionation. Thirteen lipid classes were identified and quantified in samples of standard lipid mixtures and marine lipids using the proposed development solvent systems. Iatroscan analysis is a novel technique that is rapid, sensitive, easy to handle and exhibits a high reproducibility. | en |
heal.fullTextAvailability | true | |
heal.conferenceName | 6th Euro Fed Lipid Congress: Oils, Fats and Lipids in the 3rd Millennium | en |
heal.conferenceItemType | poster |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: