Εμφάνιση απλής εγγραφής

dc.contributor.author Παναγάκης, Παναγιώτης el
dc.contributor.author Αξαόπουλος, Πέτρος Ι. el
dc.date.accessioned 2015-01-08T15:23:40Z
dc.date.available 2015-01-08T15:23:40Z
dc.date.issued 2015-01-08
dc.identifier.uri http://hdl.handle.net/11400/3550
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source American Society of Agricultural and Biological Engineers en
dc.subject Swine housing
dc.subject Heat stress
dc.subject Χοιροστάσιο
dc.subject Θερμική πίεση
dc.title Simulation comparison of evaporative pads and fogging on air temperatures inside a growing swine building en
heal.type journalArticle
heal.classification Agriculture
heal.classification Livestock
heal.classification Γεωργία
heal.classification Κτηνοτροφία
heal.classificationURI http://skos.um.es/unescothes/C00112
heal.classificationURI http://skos.um.es/unescothes/C02327
heal.classificationURI **N/A**-Γεωργία
heal.classificationURI **N/A**-Κτηνοτροφία
heal.keywordURI http://lod.nal.usda.gov/9258
heal.keywordURI http://lod.nal.usda.gov/1731
heal.identifier.secondary ISSN 0001−2351
heal.language en
heal.access free
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Ενεργειακής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2006
heal.bibliographicCitation Panagakis, P. and Axaopoulos, P. (2006). Simulation comparison of evaporative pads and fogging on air temperatures inside a growing swine building. Transactions of the ASABE. 49(1). pp. 209-215. American Society of Agricultural and Biological Engineers. Available from: http://www.prairieswine.com en
heal.abstract Evaporative pads and fogging were compared with regards to resulting air temperatures inside a growing swine building and reduction of apparent growing swine heat stress. Four strategies were studied via simulation, namely: strategy ‘a’ = no cooling, strategy ‘b’ = use of evaporative pads, strategy ‘c’ = use of fogging with the same amount of water evaporating as within the evaporative pads, and strategy ‘d’ = use of fogging with the necessary water evaporating so as to result in the same intensity of heat stress as strategy ‘b’. Indices such as the THI, the number of hours that the THI was above 85, and the duration and intensity of heat stress were used. Among all, strategy ‘b’ was considered the most effective, because it resulted in smaller daily inside dry−bulb temperature variation, maximum reduction of apparent heat stress intensity, and lower total consumption of water. en
heal.publisher American Society of Agricultural and Biological Engineers en
heal.journalName Transactions of the ASABE en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: transaction_2006.pdf
    Μέγεθος: 279.8Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες