Εμφάνιση απλής εγγραφής

dc.contributor.author Λιάσκος, Μελέτης el
dc.contributor.author Μιχαήλ, Χρήστος Μ. el
dc.contributor.author Καλύβας, Νεκτάριος Ι. el
dc.contributor.author Τουτουντζής, Ανδριανός Ε. el
dc.contributor.author Τσαντής, Σταύρος el
dc.date.accessioned 2015-01-21T10:11:07Z
dc.date.available 2015-01-21T10:11:07Z
dc.date.issued 2015-01-21
dc.identifier.uri http://hdl.handle.net/11400/4408
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source [χ.ό.] el
dc.subject Contrast detail analysis
dc.subject Radiography, Medical--Digital techniques--Congresses
dc.subject Λεπτομερής ανάλυση αντίθεσης
dc.subject Ψηφιακή ακτινογραφία
dc.title Implementation of a software phantom for the assessment of contrast detail in digital radiography en
heal.type journalArticle
heal.classification Medicine
heal.classification Medical technology
heal.classification Ιατρική
heal.classification Ιατρική τεχνολογία
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://skos.um.es/unescothes/C02465
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Ιατρική τεχνολογία
heal.keywordURI http://id.loc.gov/authorities/subjects/sh2010109376
heal.contributorName Φούντος, Γεώργιος Π. el
heal.contributorName Κάβουρας, Διονύσης Α. el
heal.contributorName Κανδαράκης, Ιωάννης Σ. el
heal.identifier.secondary ISSN 17905613
heal.language en
heal.access free
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.bibliographicCitation Liaskos, M., Michail, C., Kalyvas, N., Toutountzis, A., Tsantis, S., et al. Implementation of a software phantom for the assessment of contrast detail in digital radiography. e-Journal of Science & Technology. (15). pp. 15-23. Available from: http://e-jst.teiath.gr en
heal.abstract The aim of the present study is to simulate a commercial contrast detail phantom - (CDRAD 2.0 phantom) used in the evaluation of both digital and analog radiographic units. This phantom is suitable for the estimation of low contrast resolution. The software phantom was developed in the Matlab 7.01 platform. The results of the software phantom were evaluated with the ones obtained on a digital radiographic unit (DIAGNOST Philips Medical Systems) and showed a very good agreement. The software phantom uses tabulated data for the X-ray spectra and attenuation coefficients in order to simulate the CDRAD images as well as the contrast details versus X-ray energy and phantom depth. This software phantom provides an easy, fast and reliable method for the evaluation of contrast detail in radiographic units (both digital and analog) with the use of a personal computer. en
heal.publisher [χ.ό.] el
heal.journalName e-Journal of Science & Technology en
heal.journalName e-Περιοδικό Επιστήμης & Τεχνολογίας el
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες