dc.subject Pulse oximeters
dc.subject Infrared equipment--Calibration--Congresses
dc.subject Παλμικό οξύμετρο
dc.subject Βαθμονόμηση
dc.title Design and validation of a pulse oximeter calibrator en
heal.type journalArticle
heal.classification Medicine
heal.classification Medical technology
heal.classification Ιατρική
heal.classification Ιατρική τεχνολογία
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://skos.um.es/unescothes/C02465
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Ιατρική τεχνολογία
heal.keywordURI http://id.loc.gov/authorities/subjects/sh97006764
heal.keywordURI http://id.loc.gov/authorities/subjects/sh2010006956
heal.contributorName Avgerinos, J. el
heal.contributorName Μπενέκος, Κ. el
heal.contributorName Βαλαής, Ιωάννης Γ. el
heal.contributorName Ικιάδης, Α. el
heal.contributorName Gil-Rodriguez, J. en
heal.contributorName Wouters, P. en
heal.contributorName Meyfroidt, G. en
heal.contributorName Ponz, L. en
heal.contributorName Gehring, H. en
heal.dateAvailable 10000-01-01
heal.language en
heal.access forever
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.bibliographicCitation Hornberger, C., Matz, H., Konecny, E., Frankenberger, H., Bonk, R., et al. Design and validation of a pulse oximeter calibrator. Anesthesia and Analgesia. en
heal.abstract The performance of a new calibrator for pulse oximeters is tested with five pulse oximeters from different manufacturers. The calibrator is based on time resolved transmission spectra of human fingers. Finger spectra with different arterial oxygen saturation can be selected to simulate real patients. The results obtained with this calibration device are compared with the results of conventional calibration procedures with volunteers. Beside accuracy tests the suitability for artifact simulation with the new device is discussed. The response of the five tested pulse oximeters is in good agreement with the response of the pulse oximeters connected to real patients. A test procedure for pulse oximeters similar to the conventional desaturation practice is possible; some of the typical artifacts pulse oximetry has to cope with can be simulated easily. en
heal.publisher [χ.ό.] en
heal.journalName Anesthesia and Analgesia en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: 2-Design and validation of a ...
    Μέγεθος: 100.2Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες