Εμφάνιση απλής εγγραφής

dc.contributor.author Ματσόπουλος, Γεώργιος Κ. el
dc.contributor.author Ασβεστάς, Παντελής Α. el
dc.contributor.author Δελήμπασης, Κωνσταντίνος Κ. el
dc.contributor.author Κουλουλίας, Βασίλειος el
dc.contributor.author Ουζούνογλου, Νικόλαος Κ. el
dc.date.accessioned 2015-02-08T10:21:54Z
dc.date.available 2015-02-08T10:21:54Z
dc.date.issued 2015-02-08
dc.identifier.uri http://hdl.handle.net/11400/5839
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.hindawi.com/ en
dc.subject Registration system
dc.subject Radiotherapy
dc.subject Σύστημα καταγραφής
dc.subject Ακτινοθεραπεία
dc.title ESTERR-PRO en
heal.type journalArticle
heal.secondaryTitle a setup verification software system using electronic portal imaging en
heal.classification Medicine
heal.classification Medical technology
heal.classification Ιατρική
heal.classification Ιατρικά όργανα και εξοπλισμός
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://skos.um.es/unescothes/C02465
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Ιατρικά όργανα και εξοπλισμός
heal.identifier.secondary DOI: 10.1155/2007/61523
heal.language en
heal.access campus
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2007
heal.bibliographicCitation Matsopoulos, G., Asvestas, P., Delibasis, K., Kouloulias, V. and Uzunoglu, N. (2007). ESTERR-PRO: a setup verification software system using electronic portal imaging. International Journal of Biomedical Imaging 2007. vol. 2007. Article ID 61523. Hindawi Publishing Corporation. Available from: http://www.hindawi.com/ en
heal.abstract The purpose of the paper is to present and evaluate the performance of a new softwarebased registration system for patient set-up verification, during radiotherapy, using electronic portal images. The estimation of set-up errors, using the proposed system, can be accomplished by means of registering the portal image of the current fraction of the treatment with the portal image of the first image of the treatment (reference portal image) by applying a nearly automated technique. The proposed system was tested on data obtained by a phantom as well as on data from four patients. The phantom data included portal images that corresponded to various positions of the phantom on the treatment couch. For each patient, a set of thirty portal images were used. The accuracy of the system was (in average) better than 1 mm and the estimated set-up error was very close to the expected one. en
heal.publisher Hindawi Publishing Corporation en
heal.journalName International Journal of Biomedical Imaging en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες