dc.contributor.author | Κανδαράκης, Ιωάννης Σ. | el |
dc.contributor.author | Κάβουρας, Διονύσης Α. | el |
dc.contributor.author | Κανελλόπουλος, Ε. | el |
dc.contributor.author | Νομικός, Κωνσταντίνος Δ. | el |
dc.contributor.author | Παναγιωτάκης, Γεώργιος Σ. | el |
dc.date.accessioned | 2015-05-04T10:42:26Z | |
dc.date.available | 2015-05-04T10:42:26Z | |
dc.date.issued | 2015-05-04 | |
dc.identifier.uri | http://hdl.handle.net/11400/9640 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://www.sciencedirect.com/science/article/pii/S1350448798000584 | en |
dc.subject | Phosphor | |
dc.subject | Medical X-ray imaging | |
dc.subject | Φώσφορος | |
dc.subject | Ιατρικές απεικονίσεις με ακτίνες Χ | |
dc.title | Image quality evaluation of YVO4:Eu phosphor screens for use in x-ray medical imaging detectors | en |
heal.type | journalArticle | |
heal.classification | Medicine | |
heal.classification | Physics | |
heal.classification | Ιατρική | |
heal.classification | Φυσική | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://skos.um.es/unescothes/C02994 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Φυσική | |
heal.identifier.secondary | doi:10.1016/S1350-4487(98)00058-4 | |
heal.language | en | |
heal.access | campus | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 1998 | |
heal.bibliographicCitation | Kandarakis, I., Cavouras, D., Kanellopoulos, E., Nomicos, D. and Panayiotakis, G. (October 1998). Image quality evaluation of YVO4:Eu phosphor screens for use in x-ray medical imaging detectors. Radiation Measurements. 29(5). pp. 481-486. Elsevier Science Ltd: 1998. Available from: http://www.sciencedirect.com/science/article/pii/S1350448798000584 [Accessed 16/11/1998] | en |
heal.abstract | YVO4:Eu is a phosphor material emitting red light (621 nm) and providing excellent spectral compatibility with red sensitive optical detectors. However, it has never been used in medical X-ray imaging. In this study the imaging performance of six laboratory prepared YVO4:Eu test screens with coating weights from 30 to 140 mg/cm2 was examined by evaluating the modulation transfer function (MTF), the X-ray luminescence efficiency (XLE), and the detective quantum efficiency (DQE). DQE was evaluated by employing a method based on XLE and emission spectra measurements. The 30 mg/cm2 screen had a significantly higher MTF than thicker screens while its zero frequency DQE peak value was 0.27 at 30 kVp. Results obtained indicate that YVO4:Eu may be of value for use in X-ray imaging detectors. | en |
heal.publisher | Elsevier Science Ltd | en |
heal.journalName | Radiation Measurements | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: