Εμφάνιση απλής εγγραφής

dc.contributor.author Κανδαράκης, Ιωάννης Σ. el
dc.contributor.author Κάβουρας, Διονύσης Α. el
dc.contributor.author Κανελλόπουλος, Ε. el
dc.contributor.author Νομικός, Κωνσταντίνος Δ. el
dc.contributor.author Παναγιωτάκης, Γεώργιος Σ. el
dc.date.accessioned 2015-05-04T10:42:26Z
dc.date.available 2015-05-04T10:42:26Z
dc.date.issued 2015-05-04
dc.identifier.uri http://hdl.handle.net/11400/9640
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.sciencedirect.com/science/article/pii/S1350448798000584 en
dc.subject Phosphor
dc.subject Medical X-ray imaging
dc.subject Φώσφορος
dc.subject Ιατρικές απεικονίσεις με ακτίνες Χ
dc.title Image quality evaluation of YVO4:Eu phosphor screens for use in x-ray medical imaging detectors en
heal.type journalArticle
heal.classification Medicine
heal.classification Physics
heal.classification Ιατρική
heal.classification Φυσική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://skos.um.es/unescothes/C02994
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Φυσική
heal.identifier.secondary doi:10.1016/S1350-4487(98)00058-4
heal.language en
heal.access campus
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 1998
heal.bibliographicCitation Kandarakis, I., Cavouras, D., Kanellopoulos, E., Nomicos, D. and Panayiotakis, G. (October 1998). Image quality evaluation of YVO4:Eu phosphor screens for use in x-ray medical imaging detectors. Radiation Measurements. 29(5). pp. 481-486. Elsevier Science Ltd: 1998. Available from: http://www.sciencedirect.com/science/article/pii/S1350448798000584 [Accessed 16/11/1998] en
heal.abstract YVO4:Eu is a phosphor material emitting red light (621 nm) and providing excellent spectral compatibility with red sensitive optical detectors. However, it has never been used in medical X-ray imaging. In this study the imaging performance of six laboratory prepared YVO4:Eu test screens with coating weights from 30 to 140 mg/cm2 was examined by evaluating the modulation transfer function (MTF), the X-ray luminescence efficiency (XLE), and the detective quantum efficiency (DQE). DQE was evaluated by employing a method based on XLE and emission spectra measurements. The 30 mg/cm2 screen had a significantly higher MTF than thicker screens while its zero frequency DQE peak value was 0.27 at 30 kVp. Results obtained indicate that YVO4:Eu may be of value for use in X-ray imaging detectors. en
heal.publisher Elsevier Science Ltd en
heal.journalName Radiation Measurements en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: Image quality evaluation of ...
    Μέγεθος: 372.7Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες