Εμφάνιση απλής εγγραφής

dc.contributor.author Μιχαήλ, Χρήστος Μ. el
dc.contributor.author Νικολακέας, Σ. el
dc.contributor.author Παπαοδυσσεύς, Κωνσταντίνος el
dc.contributor.author Βεντούρας, Ερρίκος Μ. el
dc.contributor.author Ουζούνογλου, Νικόλαος Κ. el
dc.date.accessioned 2015-01-25T17:38:59Z
dc.date.issued 2015-01-25
dc.identifier.uri http://hdl.handle.net/11400/4713
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject Bioelectric potentials
dc.subject Medical electronics
dc.subject Βιοηλεκτρικό δυναμικό
dc.subject Βιοϊατρικά ηλεκτρονικά
dc.title A measurement system for acquisition, inversion and visualisation of the human body surface potential en
heal.type conferenceItem
heal.generalDescription Proceedings of the IEEE Instrumentation and Measurement Technology Conference, vol.2 en
heal.classification Medicine
heal.classification Biomedical engineering
heal.classification Ιατρική
heal.classification Βιοϊατρική τεχνολογία
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85014237
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Βιοϊατρική τεχνολογία
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85082924
heal.identifier.secondary DOI: 10.1109/IMTC.1996.507610
heal.dateAvailable 10000-01-01
heal.language en
heal.access forever
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 1996
heal.bibliographicCitation Michael, C., Nikolakeas, S., Papaodysseus, K., Ventouras, E. and Uzunoglu, N. (1996). A measurement system for acquisition, inversion and visualisation of the human body surface potential. In the IEEE Instrumentation and Measurement Technology Conference. vol. 2. pp. 1448-1451. Brussels, 4th June - 6th June 1996. en
heal.abstract A measurement system is presented, consisting of data acquisition modules and a software-implemented algorithm for inverting human body surface potentials to biological electric sources. Systems to measure event related brain potentials have been developed and used in clinical practice. Parallel techniques are being used to present three dimensional intracardiac electric current sources. Electromagnetic theory techniques are employed to link the measured surface potentials with biological electric current sources. Diagnostic usefulness of the technique is examined en
heal.publisher IEEE en
heal.fullTextAvailability true
heal.conferenceName IEEE Instrumentation and Measurement Technology Conference en
heal.conferenceItemType full paper


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: 34 - 1996 - ProcIEEE-IMTC 96_1448 ...
    Μέγεθος: 359.7Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες